These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. The Meter measures or tests: AC / DC voltage and current Resistance.
FLUKE 1587 FC MANUAL
Although this manual describes the operation of all models, all illustrations and examples assume use of Model 1587 FC. 6, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 VĢ000 m CAT III 1000 V, CAT IV 600 V 3000 m CAT II 1000 V, CAT III 600 V The Fluke 1587 FC, 1587, 1587T, and 1577 are battery-powered, true-RMS insulation multimeters (the Product or Meter) with a 6000-count display.
FLUKE 1587 FC FREE
Accepts optional Fluke TPAK TM magnetic hanging system to free your hands for other work.CAT III 1000V, CAT IV 600V measurement category.Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection.Remote probe, test leads, alligator clips.Maximum voltage applied to any terminal and commonĠ.

¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrumentĭischarge time 30 V prior to initialization of test
FLUKE 1587 FC FULL
² Usable to 100 kHz with full scale input Noise at low frequencies and amplitudes may affect accuracy ¹ Maximum input for specified accuracy = 10x range (1000 V max). V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. Inputs are ac-coupled and calibrated to the rms value of sine wave inputĬonversions are true-rms responding and specified from 5% to 100% of range. >120 dB dc, 50 Hz or 60 Hz (1 k unbalance)


Reduces errors and saves data for historical tracking over time Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results.PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster.Whether working on motors, generators, cables, or switch-gear, this instrument is ideally suited to help with many troubleshooting tasks. Quickly find problems by saving and comparing measurements over time on a wireless device. The 1587 FC is rugged, reliable and easy to use.Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.Prove your job is done right by quickly seeing and sharing insulation resistance test results wirelessly with your smartphone. Connect the insulation tester then keep yourself out of harm's way by monitoring your test measurements remotely. Keep yourself out of harm’s way by monitoring your test measurements remotely. Fluke 1587 FC Insulation Multimeter is rated 4.9 out of 5 by 28.
FLUKE 1587 FC DOWNLOAD
The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including: Put the paperwork down.įluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.